CHAPTER 2 TROUBLESHOOTING
– 200 –
NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Lamp Status
Continued on next page
CARD NAME
LAMP
STATUS
FAULT
CONTENT
REMEDIAL ACTION
PN-2ILCA (ILC)
ACT0-1 lamp is
not on
Abnormal opera-
tion of No.0-1 cir-
cuit
Confirm the programming data:
CM06, CM10/CM14, CMAC.
Reset the system (Push the SW1 of
MP).
PAL0-1 lamp is
on
No.0-1 Line is
short-circuiting
Check to see if the Terminal Adapter is
correctly connected and the power is on.
B10/B11/B20/
B21 lamp is
Flashing (60 IPM)
Programming is
not set up
Confirm the programming data:
CM06, CM10/CM14, CMAC.
Reset the system (Push the SW1 of
MP).
PN-8IPLA
(IP-PAD)
RUN lamp is not
flashing
Abnormal opera-
tion of IP-PAD
card
Confirm the programming data:
CM0A.
Reset the MB switch.
(Down Up Down)
If the fault cannot be cleared,
replace the card.
L0 lamp is on
LAN connection
failure
Check to see if the LAN cable is cor-
rectly connected.
LINK lamp is not
on
LAN connection
failure
Check to see if the LAN cable is
correctly connected.
Confirm the condition of the LAN
device (such as power of the HUB)
connected to the IP-PAD.
If the fault cannot be cleared,
replace the card.
1
2
1
2
1
2
3
1
2
3
JULY/01/2006
FAULT DIAGNOSIS AND TROUBLESHOOTING
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...