CHAPTER 2 TROUBLESHOOTING
– 198 –
NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Lamp Status
Continued on next page
CARD NAME
LAMP
STATUS
FAULT
CONTENT
REMEDIAL ACTION
PN-8COTT
(COT)
[For Australia]
LF lamp is on
Transmission line
fault
Search for a line fault by CMB0
Y=1 or CMF5 Y=0.
Check to see if the trunk line is
faulty.
PN-2CSIA
(CSI)
[For PCS]
OPE lamp is not
on
D-channel link is
not connected
between CSH and
CSI
Confirm the programming data:
CM06 Y=10.
Confirm if the corresponding CSH
card is removed.
If the fault cannot be cleared,
replace the card.
B00-B12 lamp is
flashing
ZT is not con-
nected to the cor-
responding circuit
No.
Confirm the programming data:
CM06, CM10/CM14, CMAD.
Confirm cable connection and the
power switch of the corresponding
ZT.
Confirm if the corresponding ZT is
in make-busy status.
PN-2CSIA-A
(CSI)
[For PHS]
OPE lamp is not
on
D-channel link is
not connected
between CSH and
CSI
Confirm the programming data:
CM06 Y=10.
Confirm if the corresponding CSH
card is removed.
If the fault cannot be cleared,
replace the card.
B00-B12 lamp is
flashing
CS is not con-
nected to the cor-
responding circuit
No.
Confirm the programming data:
CM06, CM10/CM14, CMAD.
Confirm cable connection and the
power switch of the corresponding
CS.
Confirm if the corresponding CS is
in make-busy status.
1
2
1
2
3
1
2
3
1
2
3
1
2
3
FAULT DIAGNOSIS AND TROUBLESHOOTING
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...