CHAPTER 2 TROUBLESHOOTING
– 166 –
NWA-008847-001 Rev.3.0
a6ch2001.fm
Line Status and Remedial Action for Hardware Test
• SINGLE LINE TELEPHONE
• D
term
Continued on next page
INDICATED
DATA
LINE STATUS
REMEDIAL ACTION
00
Terminal is not connected
Check the cable connection between the terminal
and the PBX.
Check to see if the cable is cut off.
01
Terminal is connected
No action is required.
02
Loop (Short circuit is made
on the line)
Check to see if a short circuit exists on the line.
03
Ring wire is grounded
Check to see if the Ring wire of the cable is grounded.
04
LC card is not mounted
Check to see if the LC card is properly mounted.
05
Test busy
No action is required.
INDICATED
DATA
LINE STATUS
REMEDIAL ACTION
00
Terminal is not connected
or Tip wire is grounded
Check the cable connection between the terminal
and the PBX.
Check to see if the cable is cut off.
Check to see if the Tip wire of the cable is
grounded.
01
Terminal is connected
No action is required.
02
Short circuit is made on the
line
Check to see if a short circuit exists on the line.
03
Ring wire is grounded
Check to see if the Ring wire of the cable is grounded.
04
DLC card is not mounted
Check to see if the DLC card is properly mounted.
05
Terminal failure
Replace the terminal with a known good one and check
to see if the same failure occurs.
1
2
1
2
3
FAULT DIAGNOSIS AND TROUBLESHOOTING
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...