CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 35 –
NWA-008847-001 Rev.3.0
a6ch1001.fm
Operating Procedure
(1) To disconnect the battery
(2) To cancel the battery disconnection
DE
+
EC0>
EC0
ST
COMMAND=
DE
+
EC0>00:1 –
00
EXE
+
EC0>00:1 – 0
0
OK
The current status is displayed by entering first data 00
(1: Battery connection)
The status is changed to battery disconnection by
entering second data 0.
DE
+
EC0>
EC0
ST
COMMAND=
DE
+
EC0>00:0 –
00
EXE
+
EC0>00:0 – 1
1
OK
The current status is displayed by entering first data 00
(0: Battery disconnection)
The status is changed to battery connection by entering
second data 1.