Remedial Action on Each Lamp Status
Continued on next page
CARD NAME
LAMP
STATUS
FAULT
CONTENT
REMEDIAL ACTION
PN-24PRTA
(PRT)
RUN lamp is not
flashing
Abnormal opera-
tion of PRT card
Confirm the programming data:
CM05 Y=0/Y=1, CM07 Y=01.
Check to see if the SENSE switch is
set as per the AP Number (04-15,
20-31) assigned by CM05 Y=0.
Reset the MB switch.
(Down Up Down)
If the fault cannot be cleared,
replace the card.
LC lamp is not on ISDN Primary
Rate D-channel
data link connec-
tion failure
Check the status of the local office line
or public network line.
CRC lamp is on
Bit Error Rate
exceeds the prede-
termined value
Check the receive line and external
equipment.
Replace the remote PRT card.
PCM lamp is on
No PCM signals
arrive from the
distant office
Check to see if the PRT cable is cor-
rectly connected.
Plug and unplug the PRT card.
Repeat this two or three times.
FRM lamp is on
Frame Alignment
signals from the
distant office can
not be received
Check the receive line and external
equipment.
Replace the remote PRT card.
RMT lamp is on
Frame Alignment
signals cannot be
sent to the remote
PBX
Check the transmission line and
external equipment.
Replace the PRT card.
AIS lamp is on
Remote PBX is in
local loopback
state
Check the switch settings of the remote
PRT card.
1
2
3
4
1
2
1
2
1
2
1
2
FAULT DIAGNOSIS AND TROUBLESHOOTING
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...