CHAPTER 2 TROUBLESHOOTING
– 173 –
NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Lamp Status
Continued on next page
CARD NAME
LAMP
STATUS
FAULT
CONTENT
REMEDIAL ACTION
PZ-PW122
(DC/DC PWR)
ON lamp is not on Operation power is
not being supplied
Confirm the cable connection of
PZ-PW121 and PZ-PW122.
Turn the PZ-PW122 SW switch
on.
Confirm the lamp indication of
PZ-PW121 all lamps.
If the fault cannot be cleared,
replace the PZ-PW122 card.
PZ-PW135
(DC/DC PWR)
MJ lamp is on
Major trouble
occurs or resident
system program is
not properly loaded
See
MN lamp is on
Minor trouble
occurs or resident
system program is
successfully loaded,
or a station line is
locked out
See
ON lamp is not on Operation power is
not being supplied
Confirm the cable connection of
PZ-PW135.
Confirm the lamp indication of
PZ-PW135 all lamps.
If the PZ-PW135 lamp has abnor-
mal condition, replace the PZ-
PW135 card.
1
2
3
4
1
2
3
FAULT DIAGNOSIS AND TROUBLESHOOTING