CHAPTER 2 TROUBLESHOOTING
– 172 –
NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Lamp Status
Continued on next page
CARD NAME
LAMP
STATUS
FAULT
CONTENT
REMEDIAL ACTION
PZ-PW121
(AC/DC PWR)
MJ lamp is on
Major trouble
occurs or resident
system program is
not properly loaded
See
MN lamp is on
Minor trouble
occurs or resident
system program is
successfully loaded,
or a station line is
locked out
See
ON lamp is not on Operation power is
not being supplied
Confirm the cable connection of
PZ-PW121.
Confirm the lamp indication of
PZ-PW121 all lamps.
If the PZ-PW121 lamp has
abnormal condition, replace the
PZ-PW121 card.
PZ-PW126
(AC/DC PWR)
MJ lamp is on
Major trouble
occurs or resident
system program is
not properly loaded
See
MN lamp is on
Minor trouble
occurs or resident
system program is
successfully loaded,
or a station line is
locked out
See
ON lamp is not on Operation power is
not being supplied
Confirm the cable connection of
PZ-PW126.
Confirm the lamp indication of
PZ-PW126 all lamps.
If the PZ-PW126 lamp has
abnormal condition, replace the
PZ-PW126 card.
1
2
3
1
2
3
FAULT DIAGNOSIS AND TROUBLESHOOTING
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...