CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 84 –
NWA-008847-001 Rev.3.0
a6ch1001.fm
DESCRIPTION
DATA
Assign the display of IN command/OUT com-
mand.
•
(1)
(2)
Y=2
03: IN command/OUT command setting
0
: Display both IN command/OUT
command
1
: Display only OUT command
2
: Display only IN command
3
: Not displayed
CCC: Clear all the data of CMF6 Y=2
Assign the displayed terminal
•
(1)
(2)
Y=2
04: Specification of displayed terminal
0 : Other than MATWorX
1 : MATWorX
NOTE:
When using the communication software, set the second data to 0.
Assign whether to insert a line feed for each
command.
•
(1)
(2)
Y=2
06: Whether to insert a line feed or not
0 : Inserted after each command
1 : Not inserted after each command
NOTE:
When executing command output in online mode (SW3 of MP card is set to 0), regardless
of second data setting, insert a line feed for each command.
Assign whether to add Minute/Second Indica-
tion to the header.
•
(1)
(2)
Y=2
07: Minute/Second Indication
0 : Add Minute/Second Indication to the
header
1 : Not add Minute/Second Indication to
the header
NOTE:
This command is effective when second data of CMF6 Y=2>06 is set to 0.
A
CMF6
B
JULY/01/2006
ONLINE MP-FP COMMAND OUTPUT
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...