5-14 Problem Solving
Table 5-1. POST Error Codes and Messages (continued)
Error Code and Message
Explanation
Action
0B71
System Temperature out of
the range
Abnormal temperature was
detected.
Turn off the power once.
Then check whether the fan
is clogged. Clean it if the fan
is covered with dust. If no
error is found or the failure is
cleared in spite of cleaning,
contact your service
representative.
0B74
The error occurred during
voltage sensor reading
An error occurred during detection
of voltage.
Contact your service
representative.
0B75
System Voltage out of range
Abnormal system voltage was
detected.
Contact your service
representative.
0B78
The error occurred during fan
sensor reading
An error was detected during read
of FAN sensor.
Contact your service
representative.
0B7C
The error occurred during the
redundant power module
confirmation
An error occurred while redundant
power supply was configured.
Contact your service
representative.
0B80
IBF or OBF Check Error
occurred by the access via
System Management
Controller
No response was issued for
access to System Management
Controller.
Contact your service
representative.
0B81
System Management
Controller Firmware CRC
check error occurred
An error occurred in firmware of
System Management Controller.
Contact your service
representative.
0B82
Hardware error of System
Management Controller
occurred
A hardware error was detected in
System Management Controller.
Contact your service
representative.
0B83
All Device of 1
st
System
Management Bus became not
able to accessed
SMBus could not be accessed via
System Management Controller.
Contact your service
representative.
0B84
Some Device of 1
st
System
Management Bus became not
able to accessed
No device could be accessed
through SMBus access via
System Management Controller.
Contact your service
representative.
0BA0
Address Array on CPU box
#1 error
Contact your service
representative.
0BA1
Address Array on CPU box
#2 error
Contact your service
representative.
0BA2
Data Array on CPU box #1
error
Contact your service
representative.
0BA3
Data Array on CPU box #2
error
Contact your service
representative.
0BAB
PCI Bus #3 connection
hardware error occurred
Contact your service
representative.
0BB0
SMBIOS – SROM data read
error
Reading SROM data failed.
Contact your service
representative.
0BB1
SMBIOS – SROM data
checksum bad
SROM data checksum was
incorrect.
Contact your service
representative.
Summary of Contents for HV8600
Page 1: ... U s e r s G u i d e Server HV8600 ...
Page 2: ...xxx ...
Page 3: ... U s e r s G u i d e Server HV8600 ...
Page 49: ...Setting Up Your System 2 7 Figure 2 2 Connecting the AC Power Cord ...
Page 146: ...5 26 Problem Solving 1041 1040 1042 1043 Power Units ...
Page 152: ...5 32 Problem Solving ...
Page 153: ...A System Cabling Before You Begin Static Precautions RAID and SCSI Bus Configuration ...
Page 158: ...A 6 System Cabling ...
Page 159: ...B Memory Configurations Memory DIMM Configurations ...
Page 162: ...B 4 Memory Configurations ...
Page 184: ...C 22 Management Application Workstation ...
Page 194: ...10 Glossary ...
Page 198: ...4 Equipment Log ...
Page 202: ...Index 4 ...
Page 203: ...xx ...
Page 204: ... 456 01505 000 ...