Problem Solving 5-11
Table 5-1. POST Error Codes and Messages (continued)
Error Code and Message
Explanation
Action
0250
System battery is dead –
Replace and run SETUP
No system battery is installed.
Contact your service
representative to install the
battery. (After restarting the
computer, start the Setup Utility
to set required values again.)
0251
System CMOS checksum
bad – Default configuration
used
Checksum of system CMOS is
not correct.
The default values were set.
Start the Setup Utility to set
required values again.
0260
System timer error
System timer error
Contact your service
representative.
0270
Real time clock error
Realtime lock error
Contact your service
representative.
0271
Check date and time setting
Realtime clock is set incorrectly. Start the Setup Utility to set the
time again. If the same error
occurs still, contact your service
representative.
0280
Previous boot incomplete –
Default configuration used
The previous activation has not
been terminated normally.
If the system is started without
any modification, it is started in
the uncached status.
Correct the setup values by
using the Setup Utility and start
the system again.
02B0
Diskette drive A error
Error in floppy disk A
Contact your service
representative.
02B1
Diskette drive B error
Error in floppy disk B
Contact your service
representative.
02B2
Incorrect Drive A type – run
SETUP
The type of drive A is incorrect.
Start the Setup Utility to set
required values again.
02B3
Incorrect Drive B type – run
SETUP
The type of drive B is incorrect.
Start the Setup Utility to set
required values again.
02D0
System cache error – Cache
disabled
System cache error
No cache can be used. Contact
your service representative.
0B1B
PCI System Error on
Bus/Device/Function
A PCI system error occurred in
bus/device/function.
Contact your service
representative.
0B1C
PCI Parity Error on
Bus/Device/Function
A PCI parity error occurred in
bus/device/function.
Contact your service
representative.
0B22
CPUs are installed out of
order
CPUs are installed in incorrect
order.
This does not indicate an error.
However, change the slot in
which the CPU is installed.
0B30
Fan 1 Alarm occurred.
Memory cooling fan error
Check whether the fan is
clogged. Clean it if the fan is
covered with dust. If no error is
found or the failure is cleared in
spite of cleaning, contact your
service representative.
0B31
Fan 2 Alarm occurred.
Memory cooling fan error
Same as above
0B32
Fan 3 Alarm occurred.
CPU cooling fan error
Same as above
Summary of Contents for HV8600
Page 1: ... U s e r s G u i d e Server HV8600 ...
Page 2: ...xxx ...
Page 3: ... U s e r s G u i d e Server HV8600 ...
Page 49: ...Setting Up Your System 2 7 Figure 2 2 Connecting the AC Power Cord ...
Page 146: ...5 26 Problem Solving 1041 1040 1042 1043 Power Units ...
Page 152: ...5 32 Problem Solving ...
Page 153: ...A System Cabling Before You Begin Static Precautions RAID and SCSI Bus Configuration ...
Page 158: ...A 6 System Cabling ...
Page 159: ...B Memory Configurations Memory DIMM Configurations ...
Page 162: ...B 4 Memory Configurations ...
Page 184: ...C 22 Management Application Workstation ...
Page 194: ...10 Glossary ...
Page 198: ...4 Equipment Log ...
Page 202: ...Index 4 ...
Page 203: ...xx ...
Page 204: ... 456 01505 000 ...