4-38
CRU Replacement and Server Upgrades
Installing a PCI Module
1.
Observe the safety and ESD precautions listed at the beginning of this
chapter.
2.
Ensure that the locking handle on the front of the PCI module is in the up
unlocked position.
3.
Support the PCI module with both hands and carefully slide it into the
chassis until it is firmly seated in its connector.
4.
Swing the locking handle all the way down to its locked position.
Figure 4-49. Securing the Locking Handle of the PCI Module
5.
Hand-tighten the knurled screw that fastens the locking handle to the PCI
module.
Note:
Hand-tighten the knurled screw only as much
required to activate the interlock switch that allows power to
be applied to the PCI module.
6.
Reconnect (if disconnected) all PCI cables and the network cable to the front
of the PCI module.
7.
Close and lock the front door on the tower cabinet or front covers on the
rack-mount system. See
Opening and Closing the Front Door of the Tower
Cabinet
earlier in this chapter or
Removing and Installing the Front Covers
of the Rack-Mount System
earlier in this chapter.
Summary of Contents for Express5800 320La
Page 1: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 2: ...NEC...
Page 3: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 40: ...1 26 System Overview...
Page 55: ...Setting Up the System 2 15 Figure 2 10 UPS AC Power Cord with 30 amp plug L5 30P...
Page 60: ...2 20 Setting Up the System...
Page 154: ...4 68 CRU Replacement and Server Upgrades...
Page 185: ...A Technical Specifications Server Unit...
Page 188: ...A 4 Technical Specifications...
Page 189: ...B ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes...
Page 192: ...B 4 ROMPilot BIOS Error Codes...
Page 202: ...10 Glossary...
Page 205: ...xx...
Page 206: ...456 01572 N00...