5-16
Problem Solving
Table 5-1. LCD Error Messages (continued)
Status Lamp
Error Message
Color State
Suspected
Module
Description
Action
CPU1 +5.0vsAlm00
Amber Blink
CPU module #1
5-V power voltage alarm (lower limit)
CPU1 +5.0vsAlm02
Amber Lit
CPU module #1
Fatal 5-V power voltage alarm (lower
limit)
CPU1 +5.0vsAlm07
Amber Blink
CPU module #1
5-V power voltage alarm (upper
limit)
CPU1 +5.0vsAlm09
Amber Lit
CPU module #1
Fatal 5-V power voltage alarm
(upper limit)
CPU1 Broken
Green
Blink
CPU module #1
CPU module failure
Contact your service
representative.
CPU1 FAN Alm 01
Amber Blink
CPU module #1
Cooling fan 1 alarm
CPU1 FAN Alm 02
Amber Blink
CPU module #1
Cooling fan 2 alarm
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
CPU FANvltAlm00
Amber Blink
CPU module #1
Voltage alarm (lower limit) of the
CPU module cooling fan
CPU FANvltAlm02
Amber Lit
CPU module #1
Fatal voltage alarm (lower limit) of
the CPU module cooling fan
CPU FANvltAlm07
Amber Blink
CPU module #1
Voltage alarm (upper limit) of the
CPU module cooling fan
CPU FANvltAlm09
Amber Lit
CPU module #1
Fatal voltage alarm (upper limit) of
the CPU module cooling fan
CPU1 Missing
Green
Blink
CPU module #1
CPU not found
Contact your service
representative.
CPU1 offline
Green
Blink
CPU module #1
The CPU module has been logically
disconnected.
Activate the ft server utility, or
remove the module and then
mount it again. If the same
error message is still
displayed, contact your
service representative.
CPU1 removed
Green
Blink
CPU module #1
The CPU module has come off.
Check the module for a
removed screw, or remove the
module and then mount it
again. If the same error
message is still displayed,
contact your service
representative.
CPU1 Temp Alm 00
Amber Blink
CPU module #1
Temperature alarm (lower limit)
CPU1 Temp Alm 02
Amber Lit
CPU module #1
Fatal temperature alarm (lower limit)
CPU1 Temp Alm 07
Amber Blink
CPU module #1
Temperature alarm (upper limit)
CPU1 Temp Alm 09
Amber Lit
CPU module #1
Fatal temperature alarm (upper limit)
CPU11 TempAlm 00
Amber Blink
CPU module #1
CPU#1 temperature alarm (lower
limit)
CPU11 TempAlm 02
Amber Lit
CPU module #1
Fatal CPU#1 temperature alarm
(lower limit)
CPU11 TempAlm 07
Amber Blink
CPU module #1
CPU#1 temperature alarm (upper
limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
Summary of Contents for Express5800 320La
Page 1: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 2: ...NEC...
Page 3: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 40: ...1 26 System Overview...
Page 55: ...Setting Up the System 2 15 Figure 2 10 UPS AC Power Cord with 30 amp plug L5 30P...
Page 60: ...2 20 Setting Up the System...
Page 154: ...4 68 CRU Replacement and Server Upgrades...
Page 185: ...A Technical Specifications Server Unit...
Page 188: ...A 4 Technical Specifications...
Page 189: ...B ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes...
Page 192: ...B 4 ROMPilot BIOS Error Codes...
Page 202: ...10 Glossary...
Page 205: ...xx...
Page 206: ...456 01572 N00...