1-16
System Overview
For true dual modular redundancy, all the disk drives must be mirrored in the system, as
shown below.
Mirrored Drives
Drive
Drive
1
4
2
5
3
6
All the disk drives must be added in pairs and only similar disks can mirror each other.
Figure 1-10.
G ro u p 1
G ro u p 2
Figure 1-10. Mirrored Hard Disk Drives
Table 1-9 summarizes the features of storage bays and hard disk drives.
Table 1-9. Features of the Storage Bays and Hard Disk Drives
Feature
Description
Disk drives
Hot pluggable and redundant.
Disk drive speeds
and storage
capacity
Disk drive spindle speeds of 10,000 RPM. Storage capacities of 18, or 36 GB.
Disk drive carrier
Each disk drive is mounted in a disk drive carrier containing a handle, latching
mechanism, and two status indicators. The status indicators are listed along
with a description of each in Table 1-2.
Storage bays
The storage bays can contain any combination of disk drive carriers and
dummy disk drive carriers as long as equivalent drives are mirrored.
DO NOT remove dummy disk drive carriers from unused slots. They are
present to direct airflow around the devices.
Summary of Contents for Express5800 320La
Page 1: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 2: ...NEC...
Page 3: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 40: ...1 26 System Overview...
Page 55: ...Setting Up the System 2 15 Figure 2 10 UPS AC Power Cord with 30 amp plug L5 30P...
Page 60: ...2 20 Setting Up the System...
Page 154: ...4 68 CRU Replacement and Server Upgrades...
Page 185: ...A Technical Specifications Server Unit...
Page 188: ...A 4 Technical Specifications...
Page 189: ...B ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes...
Page 192: ...B 4 ROMPilot BIOS Error Codes...
Page 202: ...10 Glossary...
Page 205: ...xx...
Page 206: ...456 01572 N00...