CRU Replacement and Server Upgrades 4-25
11.
Reconnect the power cable of cooling fan #1 to its connector on the CPU
board and slide the fan back into its holder located in the front portion of the
CPU module. See Figure 4-28.
Frame
Fan
Figure 4-28. Installing Cooling Fan #1
12.
Reinstall the top cover of the CPU module. See
Installing a Processor
earlier in this chapter.
Removing DIMMs
1.
Remove the appropriate CPU module from the server chassis. See
Removing
a CPU Module
earlier in this chapter.
2.
Remove the top cover of the CPU module. See
Installing a Processor
earlier
in this chapter.
3.
Slide and remove cooling fan #1 located in the front portion of the CPU
module. See Figure 4-24.
Figure 4-29. Removing Cooling Fan #1