4-24
CRU Replacement and Server Upgrades
6.
Spread the latch levers located on both ends of the DIMM socket just
enough to unlock the DIMM cover and remove it (see Figure 4-26).
Note:
A DIMM cover is always mounted in an empty
DIMM socket.
Figure 4-26. Removing a DIMM Cover
7.
Holding the DIMM module only by its edges, remove it from its antistatic
package.
!
CAUTION
Observe static precautions. Use an antistatic wrist strap.
Hold DIMMs only by their edges.
8.
DIMMs are keyed so they can only be inserted one way. Position the DIMM
over the socket on the CPU board. The notches in the bottom edge of the
DIMM mates with the raised bumps in the DIMM socket. See Figure 4-27.
9.
Press down evenly on the DIMM until it seats correctly. The socket levers
are not tools to aid in the insertion, only to keep the DIMM's in place and to
aid in extraction. The levers should automatically click in place once the
DIMM is fully inserted.
Figure 4-27. Installing a DIMM
10.
Repeat steps 6 through 8 to install additional DIMMs.
Summary of Contents for Express5800 320La
Page 1: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 2: ...NEC...
Page 3: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 40: ...1 26 System Overview...
Page 55: ...Setting Up the System 2 15 Figure 2 10 UPS AC Power Cord with 30 amp plug L5 30P...
Page 60: ...2 20 Setting Up the System...
Page 154: ...4 68 CRU Replacement and Server Upgrades...
Page 185: ...A Technical Specifications Server Unit...
Page 188: ...A 4 Technical Specifications...
Page 189: ...B ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes...
Page 192: ...B 4 ROMPilot BIOS Error Codes...
Page 202: ...10 Glossary...
Page 205: ...xx...
Page 206: ...456 01572 N00...