System Overview 1-3
This server system is designed for full redundancy and hot plug replacement of all
major subsystems. The system modules that can be replaced are identified as Customer
Replaceable Units (CRUs) of which most are redundant and hot pluggable. To this end,
the server includes or has the option to include the following:
!
Two self-contained power supplies that provide redundant power (i.e., the system
will continue to operate with a single power supply failure) and are hot swappable.
The two power supplies are easily installed or removed from the back of the chassis
without turning the system power off.
!
Cooling system redundancy where the system will continue to operate in the event of
a fan failure and the redundant fans will switch to maximum operating speed.
!
SCSI hard disk drive bays accessible from the front of the chassis.
!
Hot-swap SCSI disk drive backplane; a failed drive can be removed and replaced
with a new drive without system power being turned off.
!
High degree of SCSI disk fault tolerance and advanced disk array management
features.
!
Video Graphics Array (VGA) controller with 4 MB of video memory (occupies one
PCI slot per PCI module).
!
SCSI disk adapter providing dual channel Ultra 160 SCSI interfaces for the hot swap
hard disk drives.
!
Embedded single channel enhanced IDE adapter providing interface for peripheral
devices (CD-ROM and super floppy disk drive).
!
Integrated onboard Network Interface Controller (NIC), an Intel 82559 PCI LAN
adapter for 10 or 100 Mbps Ethernet networks with a RJ-45 Ethernet connector.
!
Storage module that holds up to six hot-swap SCSI hard disk drives (three logical
disks).
!
SCSI backpanel is Ultra2 capable.
!
Integrated dual Universal Serial Bus (USB) ports that include support for the
keyboard and mouse.
!
Hardware monitors (temperature, fans, and voltage) and software monitors to
indicate failures.
!
Hardware monitors (temperature and voltage) and software monitors to indicate
failures.
!
Easy access to all parts for service.
Summary of Contents for Express5800 320La
Page 1: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 2: ...NEC...
Page 3: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 40: ...1 26 System Overview...
Page 55: ...Setting Up the System 2 15 Figure 2 10 UPS AC Power Cord with 30 amp plug L5 30P...
Page 60: ...2 20 Setting Up the System...
Page 154: ...4 68 CRU Replacement and Server Upgrades...
Page 185: ...A Technical Specifications Server Unit...
Page 188: ...A 4 Technical Specifications...
Page 189: ...B ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes...
Page 192: ...B 4 ROMPilot BIOS Error Codes...
Page 202: ...10 Glossary...
Page 205: ...xx...
Page 206: ...456 01572 N00...