5-22
Problem Solving
Table 5-1. LCD Error Messages (continued)
Status Lamp
Error Message
Color State
Suspected
Module
Description
Action
PCI1 Temp Alm 00
Amber Blink
PCI module #1
Temperature alarm (lower limit)
PCI1 Temp Alm 02
Amber Lit
PCI module #1
Fatal temperature alarm (lower limit)
PCI1 Temp Alm 07
Amber Blink
PCI module #1
Temperature alarm (upper limit)
PCI1 Temp Alm 09
Amber Lit
PCI module #1
Fatal temperature alarm (upper limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
PCI2 +12v Alm 00
Amber Blink
PCI module #2
12-V power voltage alarm (lower limit)
PCI2 +12v Alm 02
Amber Lit
PCI module #2
Fatal 12-V power voltage alarm (lower
limit)
PCI2 +12v Alm 07
Amber Blink
PCI module #2
12-V power voltage alarm (upper
limit)
PCI2 +12v Alm 09
Amber Lit
PCI module #2
Fatal 12-V power voltage alarm
(upper limit)
PCI2 +3.3vAlm 00
Amber Blink
PCI module #2
3.3-V power voltage alarm (lower
limit)
PCI2 +3.3vAlm 02
Amber Lit
PCI module #2
Fatal 3.3-V power voltage alarm
(lower limit)
PCI2 +3.3vAlm 07
Amber Blink
PCI module #2
3.3-V power voltage alarm (upper
limit)
PCI2 +3.3vAlm 09
Amber Lit
PCI module #2
Fatal 3.3-V power voltage alarm
(upper limit)
PCI2 +3.3vsAlm00
Amber Blink
PCI module #2
3.3-V power voltage alarm (lower
limit)
PCI2 +3.3vsAlm02
Amber Lit
PCI module #2
Fatal 3.3-V power voltage alarm
(lower limit)
PCI2 +3.3vsAlm07
Amber Blink
PCI module #2
3.3-V power voltage alarm (upper
limit)
PCI2 +3.3vsAlm09
Amber Lit
PCI module #2
Fatal 3.3-V power voltage alarm
(upper limit)
PCI2 +5.0vAlm 00
Amber Blink
PCI module #2
5-V power voltage alarm (lower limit)
PCI2 +5.0vAlm 02
Amber Lit
PCI module #2
Fatal 5-V power voltage alarm (lower
limit)
PCI2 +5.0vAlm 07
Amber Blink
PCI module #2
5-V power voltage alarm (upper limit)
PCI2 +5.0vAlm 09
Amber Lit
PCI module #2
Fatal 5-V power voltage alarm (upper
limit)
Contact your service
representative.
PCI2 Temp Alm 00
Amber Blink
PCI module #2
Temperature alarm (lower limit)
PCI2 Temp Alm 02
Amber Lit
PCI module #2
Fatal temperature alarm (lower limit)
PCI2 Temp Alm 07
Amber Blink
PCI module #2
Temperature alarm (upper limit)
PCI2 Temp Alm 09
Amber Lit
PCI module #2
Fatal temperature alarm (upper limit)
Check if the internal fan is
clean and if the internal fan
cable is connected firmly. If
the same error message is
still displayed, contact your
service representative.
Power Major Alm
Amber Lit
Power unit #1/2
Fatal power (major) alarm
Contact your service
representative.
Power On Cnt Alm
Amber Lit
Power unit #1/2
Fatal power control system failure
Check the AC cable. If the
same error message is still
displayed, contact your
service representative.
Summary of Contents for Express5800 320La
Page 1: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 2: ...NEC...
Page 3: ...U s e r s G u i d e EXPRESS5800 320La 320La R...
Page 40: ...1 26 System Overview...
Page 55: ...Setting Up the System 2 15 Figure 2 10 UPS AC Power Cord with 30 amp plug L5 30P...
Page 60: ...2 20 Setting Up the System...
Page 154: ...4 68 CRU Replacement and Server Upgrades...
Page 185: ...A Technical Specifications Server Unit...
Page 188: ...A 4 Technical Specifications...
Page 189: ...B ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes...
Page 192: ...B 4 ROMPilot BIOS Error Codes...
Page 202: ...10 Glossary...
Page 205: ...xx...
Page 206: ...456 01572 N00...