机架式服务器

上架安装指南

V1.0

请注意!

Rack-mounted Server

Installation Guide

          

    (Drop-in Rail) 

Warnings!

 

  

 

 

   

 

   

 

   

 

   

 

   

 

   

 

   

.

.

Please keep this document for future reference.

请保留本文档,以便于日后查阅。

15kg

30kg

50kg

(一体式导轨)

PN

The cabinet, chassis or guide rails may cause serious scratches, please be careful while handling.

机柜或者服务器机箱、导轨可能造成划伤!

When installing new servers into the cabinet in use, please be aware of electric shock.

在正在使用的机柜中安装新服务器时,请谨防触电!

When installing 4U or bigger servers, at least 4 people are needed.

安装

4U

或更大机型时,至少需要

4

个人。

During the installation process, please do not block the vents on the server, especially the 

vents on the front and rear of the server.

安装时请注意不要阻塞服务器上的通风孔,尤其是服务器前、后部的通风孔。

Please remove the protective film from the server surface before using.

请在使用之前将服务器外壳上的保护膜撕去。

Please leave a minimum of 15cm clearance on the front and rear sides of the server for 

proper ventilation.

服务器的前、后部需至少留出

15

厘米空间,以便于系统散热。

Please install air baffles in place prior to device installation, to make sure that the server can 

get enough air flow, and to avoid air turbulence in the server room.

没有安装设备的机柜位置,请始终安装挡风盲板,以确保服务器获得足够的气流,并避免机
房气流紊乱。

Servers are high-power electrical appliances, and they should be installed into dedicated 

cabinets with vents or professional water-cooled cabinets, to prevent system failures 

causedby overheating.

服务器是高功耗电器,只能安装在带有通风孔的专用机柜,或者专业水冷机柜中,以免过热
造成系统失效。

If it needs to install more than one device, please load them from the bottom to the top, and 

load the heaviest items first.

如果要安装多台设备,请先从机柜靠下的空位开始,并将较重的设备安装在机柜下部。

Please note the cabinet’s load-bearing capacity, power supply capacity and heat dissipation 

capacity, be sure not to install devices beyond the cabinet’s threshold capacity.

请注意机柜的承重、供电及散热能力,切勿安装超出机柜承载能力的设备。

For the convenience of using the front and rear ports of the server and cabling, leave a 

minimumclearanceof 70mm between the front end of the server and the inner side of the 

cabinet’sfront door, and 150mm between the rear end of the server andthe inner side of the 

cabinet’s rear door.

为了便于使用服务器前、后部的接口,并便于布线,服务器前部与机柜前门内侧之间至少留

70

毫米、后部与机柜后门内侧之间至少留出

150

毫米距离。

If the device is more than 15kg, at least 2 people are needed.

安装超过

15

千克的设备时,至少需要

2

个人!

If the device is more than 30kg, at least 3 people are needed.

安装超过

30

千克的设备时,至少需要

3

个人!

If the device is more than 50kg, at least 4 people are needed.

安装超过

50

千克的设备时,至少需要

4

个人!