![NEC Express 5800/320Lc User Manual Download Page 59](http://html1.mh-extra.com/html/nec/express-5800-320lc/express-5800-320lc_user-manual_4266933059.webp)
General Description 2-25
LED indications
Primary Secondary
Description Action
Detected a fatal
temperature error.
If LCD displays some error message,
refer to the error message list (see
Chapter 7).
Check if dust is accumulated on internal
fans and confirm that the fan cables are
connected firmly. If the message does
not disappear, contact your sales agent.
Amber Off
Detected a fatal voltage
error.
Contact your sales agent.
Detected a temperature
error to be warned.
If LCD displays some error message,
refer to the error message list (see
Chapter 7).
Check if dust is accumulated on internal
fans and confirm that the fan cables are
connected firmly. If the message does
not disappear, contact your sales agent.
Detected a voltage error to
be warned.
Detected a device defect.
Contact your sales agent.
Amber
(blinking
every 1
second)
Off
Detected a fan alarm.
If LCD displays some error message,
refer to the error message list (see
Chapter 7).
Check if dust is accumulated on internal
fans, and confirm that the fan cables are
connected firmly. If the message does
not disappear, contact your sales agent.
BMC is being dumped.
Wait for a while; it will go off soon.
PCI module may be
connected incorrectly.
Check if PCI module is connected
correctly. Look for loose screws.
Red Off
BMC may be out of order.
BMC firmware may need
reprogramming. Contact your sales
agent.
BMC is being dumped.
Wait for a while. After a while, the BMC
status LED on the secondary will blink.
PCI module may be
connected incorrectly.
Check if PCI module is connected
correctly. Look for loose screws.
ANY*
1
Red
BMC may be out of order.
BMC firmware may need to be
rewritten. Contact your sales agent.
ANY*
1
Red
(blinking
every 0.5
second)
Transfers data being
synchronized after a PCI
module is replaced (this is
not an error).
Do not remove either of the PCI
modules or control the AC/DC power
until the LED stops blinking.
ANY*
1
Red
(blinking
every 1
second)
The revision of BMC
firmware does not match.
Contact your sales agent.
Summary of Contents for Express 5800/320Lc
Page 10: ...iv This page is intentionally left blank...
Page 20: ...1 6 Precautions for Use PCI CPU Modules PCI Module Label A CPU Module Label A Label A...
Page 34: ...1 20 Precautions for Use This page is intentionally left blank...
Page 50: ...2 16 General Description Front View inside Tower model Rack mount model...
Page 94: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume...
Page 132: ...3 52 Windows Setup and Operation This page is intentionally left blank...
Page 256: ...5 80 Installing and Using Utilities This page is intentionally left blank...
Page 362: ...8 52 System Upgrade This page is intentionally left blank...