3-34 Windows Setup and Operation
10.
Open the disk’s properties to check the target IDs. In the following figures, disks are
configured as:
Disk 1: Target ID 1
Disk 2: Target ID 2
Disk 4: Target ID 1
Disk 5: Target ID 2
Disks with the same target ID are mirrored.
Disk 1 Disk 2
Disk 4 Disk 5
IMPORTANT:
Hard disks are numbered from “0” at the OS startup according to the
position they are inserted. When you increase a hard disk while the system is running, it
will be given a number that is not used for any disks. However when you restart the
system, the old disk numbers will not be retained and disks are re-numbered according
to the hard disk position. Therefore, you need to determine which disks are mirrored
based on target IDs, which are always fixed, but not on disk numbers because disk
numbers may change.
Summary of Contents for Express 5800/320Lc
Page 10: ...iv This page is intentionally left blank...
Page 20: ...1 6 Precautions for Use PCI CPU Modules PCI Module Label A CPU Module Label A Label A...
Page 34: ...1 20 Precautions for Use This page is intentionally left blank...
Page 50: ...2 16 General Description Front View inside Tower model Rack mount model...
Page 94: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume...
Page 132: ...3 52 Windows Setup and Operation This page is intentionally left blank...
Page 256: ...5 80 Installing and Using Utilities This page is intentionally left blank...