![NEC Express 5800/320Lc User Manual Download Page 300](http://html1.mh-extra.com/html/nec/express-5800-320lc/express-5800-320lc_user-manual_4266933300.webp)
7-32 Troubleshooting
reason, consult your sales agent. It is possible to perform reintegration forcefully.
Source: srabid
ID: 16395
Description:
x is now STATE_BROKEN / REASON_BELLOW_MTBF (“x”
is a device number.)
An unavailable disk is displayed on Disk Management:
→
Follow the instructions on the table below:
Disk status
Description
Action
[Foreign] appears when
loading a dynamic disk
which has been used in a
different system.
[To use the disk’s data]
Referring to Chapter 3 “Windows
Setup and Operation”, import the disk.
[To change the disk to an available
disk]
To use this disk, it needs to be
initialized. It will become available
after initialization.
<Note>
Initialization erases all data on the disk.
If there is important data, back up data
before initialization.
[Missing] appears when a
dynamic disk is damaged or
removed.
If there is a volume on the missing
disk, break the mirror on that disk.
Then right-click the [Missing] disk and
perform [Remove disk].
[Not Initialized] appears
when the disk is not signed.
Right-click the disk and perform
[Initialize Disk]. The disk will become
available.
Primary PCI module’s status LED2 and DISK ACCESS LED illuminate amber after
startup:
Is the mirroring of the hard disks broken?
→
See [Disk Management] and if the mirror is broken, reconfigure it.
For mirroring configuration, see “DISK OPERATIONS” in Chapter 3 “Windows
Setup Operation.”
Other than disk failure, the mirror may be removed at startup after the following
operations:
•
Started the server after shutdown with the PCI module in simplex mode
•
Started NEC Express5800/ft series when the BMC status LED was blinking
The duplication process of Baseboard Management Controller (BMC) is executed
Summary of Contents for Express 5800/320Lc
Page 10: ...iv This page is intentionally left blank...
Page 20: ...1 6 Precautions for Use PCI CPU Modules PCI Module Label A CPU Module Label A Label A...
Page 34: ...1 20 Precautions for Use This page is intentionally left blank...
Page 50: ...2 16 General Description Front View inside Tower model Rack mount model...
Page 94: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume...
Page 132: ...3 52 Windows Setup and Operation This page is intentionally left blank...
Page 256: ...5 80 Installing and Using Utilities This page is intentionally left blank...
Page 362: ...8 52 System Upgrade This page is intentionally left blank...