System Configuration 4-41
TIPS:
A message informing you of the completion of CMOS clear and prompting you to
clear CMOS will appear for 10 seconds. Note that even if you do not do anything,
the process goes on and the server will be rebooted automatically.
8.
If the message [Non volatile memory cleared] appears after rebooting and during POST,
turn off the power by pressing the POWER switch and unplug the both power cords.
IMPORTANT:
If the message [Non volatile memory cleared] appears at normal startup, the jumper
switch is set for clearing CMOS. Change back the jumper switch setting.
Non volatile memory cleared:
This message indicates that CMOS is cleared properly.
9.
Remove the PCI Module #1 from NEC Express5800/ft series (see “Removing PCI
Module” on page 8-29).
10.
Reset the jumper switch setting.
Remove the clips from the jumper pins 1-2 and place them on the jumper pins 11-12 on
the PCI Module #1.
TIPS:
If you place clips on other pins, the server may malfunction.
11.
Mount the PCI Module #1 again to NEC Express5800/ft series (see “Installing PCI
Module” on page 8-31) and plug the power cord to the AC inlet B (for Group1).
12.
Likewise, mount the PCI Module #2 to NEC Express5800/ft series and plug the power
cord to the AC inlet A (for Group2).
Summary of Contents for Express 5800/320Lc
Page 10: ...iv This page is intentionally left blank...
Page 20: ...1 6 Precautions for Use PCI CPU Modules PCI Module Label A CPU Module Label A Label A...
Page 34: ...1 20 Precautions for Use This page is intentionally left blank...
Page 50: ...2 16 General Description Front View inside Tower model Rack mount model...
Page 94: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume...
Page 132: ...3 52 Windows Setup and Operation This page is intentionally left blank...
Page 256: ...5 80 Installing and Using Utilities This page is intentionally left blank...
Page 362: ...8 52 System Upgrade This page is intentionally left blank...