6-12 Troubleshooting
When STATUS lamp is lighting in amber:
On-screen
message
Description
Action
Proc Temp Alm 02
A low temperature alarm
is detected in processor.
Proc Temp Alm 09
A high temperature alarm
is detected in processor.
BB Temp2 Alm 02
A low temperature alarm
is detected in base board.
BB Temp2 Alm 09
A high temperature alarm
is detected in base board.
BB Temp1 Alm 02
A low temperature alarm
is detected in base board.
BB Temp1 Alm 09
A high temperature alarm
is detected in base board.
1. Check if dust or stain is adhered to the fan of
the power unit or not.
2. Check if blank cover is surely installed in the
slot which does not contain any power unit.
3. Check the ambient temperature of
installation location.
4. Take one of the following measures to reboot
(reset) the maintenance card.
* Press
Ctrl
+
Alt
+
Del
.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC
ESMPRO Manager.
5. Take one of the following measures to power
off the maintenance card and then on.
* Press the Maintenance switch to power off
the maintenance card, then press it again
to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC
ESMPRO Manager.
6. Power off the maintenance card by pressing
the Maintenance switch.
Press the POWER switch of
EcoPowerGateway to turn off the power,
then turn it on. Then, press the Maintenance
switch to turn on the maintenance card.
7. If the same error persists, contact your
service representative.
VBAT Alm 02
A voltage alarm (lower
limit) occurred on lithium
battery.
VBAT Alm 09
A voltage alarm (upper
limit) occurred on lithium
battery.
1. Take one of the following measures to power
off the maintenance card and then on.
* Press the Maintenance switch to power off
the maintenance card, then press it again
to power on.
* Issue a command from Web browser of
EXPRESSSCOPE Engine 2 or NEC
ESMPRO Manager.
2. If the same error persists, contact your
service representative.
Summary of Contents for EcoPowerGateway N8142-36F
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ... This page is intentionally left blank ...
Page 16: ...vi This page is intentionally left blank ...
Page 21: ...Notes on Using Your EcoPowerGateway 1 5 ...
Page 23: ...Notes on Using Your EcoPowerGateway 1 7 ...
Page 26: ...1 10 Notes on Using Your EcoPowerGateway ...
Page 29: ...Notes on Using Your EcoPowerGateway 1 13 ...
Page 38: ...1 22 Notes on Using Your EcoPowerGateway This page is intentionally left blank ...
Page 56: ...2 18 General Description This page is intentionally left blank ...
Page 136: ...A 2 Specifications This page is intentionally left blank ...