Chapter8. CDU Service Manual
8-22
© 2016
Nautilus Hyosung Inc.
All Rights Reserved.
►Gate Solenoid Assembly
1. Remove the solenoid power cable.
2.
Remove the φ2 E-ring.
3. Unscrew the solenoid bracket screws (M4, 2 places).
4. Unscrew the solenoid fixing screws (M4, 4 places).
5. Assemble in the reverse order
– 4 ~ 1 after replacing a solenoid assembly. Adjust