Service Manual Chapter8. CDU
© 2016
Nautilus Hyosung Inc.
All Rights Reserved.
8-13
►CS4T (A, B)
1. Remove the M3 screws (2 places) of the sensor bracket at the left and right sides.
2. Remove the connector and the cable tie to remove the sensor supporter. Be careful
not to break the connector pin when removing.
3. Remove the sensor bracket.
4. Remove the M3 sensor fastening screws of the sensor to replace from the removed
sensor bracket.
5. Replace the sensor.
6. Assemble the unit in the reverse order - 4~1.