Chapter5. Power Supply Service Manual
5-4
© 2016
Nautilus Hyosung Inc.
All Rights Reserved.
► Connector Configuration
1. AC IN
Division
PIN No.
Configuration
Size
Color
Remark
AC IN
1
L
18AWG/UL1015
BLACK
INLET
FILTER
(ID-0642-S)
2
F.G
18AWG/UL1015
GRN/YEL
3
N
18AWG/UL1015
WHITE
2. MBD
Division
PIN No.
Configuration
Size
Color
Remark
CN1
1
S.G
18AWG/UL1007
BLACK
MOLEX
(5569-20P)
2
S.G
18AWG/UL1007
BLACK
3
S.G
18AWG/UL1007
BLACK
4
S.G
18AWG/UL1007
BLACK
5
S.G
18AWG/UL1007
BLACK
6
S.G
18AWG/UL1007
BLACK
7
+5V
18AWG/UL1007
RED
8
+5V
18AWG/UL1007
RED
9
+24V
18AWG/UL1007
WHITE
10
-5V
18AWG/UL1007
ORANGE
11
P-ON-N
18AWG/UL1007
GREEN
12
+5VSBV
18AWG/UL1007
PURPLE
13
S.G
18AWG/UL1007
BLACK
14
S.G
18AWG/UL1007
BLACK
15
S.G
18AWG/UL1007
BLACK
16
POWER
GOOD
18AWG/UL1007
GRAY
17
-12V
18AWG/UL1007
BLUE
18
+5V
18AWG/UL1007
RED
19
+5V
18AWG/UL1007
RED
20
+12V
18AWG/UL1007
YELLOW
3. SHU
Division
PIN No.
Configuration
Size
Color
Remark
CN2
1
+5V
18AWG/UL1007
RED
MOLEX
(5569-08P)
2
+24V
18AWG/UL1007
WHITE
3
+12V
18AWG/UL1007
GREEN
4
S.G
18AWG/UL1007
BLACK
5
-12V
18AWG/UL1007
BLUE
6
+24V
18AWG/UL1007
WHITE
7
S.G
18AWG/UL1007
BLACK
8
S.G
18AWG/UL1007
BLACK
4. CDU
Division
PIN No.
Configuration
Size
Color
Remark
1
+5V
18AWG/UL1007
RED
2
S.G
18AWG/UL1007
BLACK