Chapter5. Power Supply Service Manual
5-6
© 2016
Nautilus Hyosung Inc.
All Rights Reserved.
10. OPL
Division
PIN No.
Configuration
Size
Color
Remark
CN11
1
+24V
18AWG/UL1007
WHITE
MOLEX
(5569-
04P)
2
+24V
18AWG/UL1007
WHITE
3
S.G
18AWG/UL1007
BLACK
4
S.G
18AWG/UL1007
BLACK
11. ETC
Division
PIN No.
Configuration
Size
Color
Remark
CN11
1
+24V
18AWG/UL1007
WHITE
MOLEX
(5569-
04P)
2
+24V
18AWG/UL1007
WHITE
3
S.G
18AWG/UL1007
BLACK
4
S.G
18AWG/UL1007
BLACK
12. PWR I/F
PIN
NO.
PIN Name
Active
(INACTIVE)
Description
IN/OUT
1
P OFF-P
+5V(0V)
Application software turn P/S off
IN
2
S.G
-
-
3
P ON-N
0V(OPEN)
Stand-by switch used to turn P/S
on
IN
4
S.G
-
-
5
BATT
OFF-N
0V(+5V)
When #7 signal go active CE
module Make
this signal active then P/S
turned off
IN
6
S.G
-
-
7
AC
STOP-N
0V(+5V)
When a stoppage of A.C power
occur
(While U.P.S run) this signal
activated
OUT
8
S.G
-
-
9
BATT
LOW-N
0V(+5V)
Active of this signal means
battery should Replaced, display
of error code required
OUT
10
S.G
-
-
11
P OFF-N
0V(OPEN)
Stand-by switch go to off
position
OUT
12
N.C
-
-
<Note!>
1) CABLE UL1007 22AWG
2) CONNECTOR MOLEX 5559-12P