CLT- & CLX-1DELV4

 

Functional Summary 

The Crestron

 1-Feed, 4-Dimmer Electronic Low Voltage 

Terminal Block and Module (CLT-1DELV4 and  
CLX-1DELV4, respectively), are considered a single 
entity and must be used together. They ship separately to 
permit termination of the field wiring to the  
CLT-1DELV4 prior to installation of the CLX-1DELV4, 
as described in this guide. They can be mounted in any 
Crestron Automation Enclosure (CAEN-Series 
Enclosures). The terminal block is designed to terminate 
the circuit feed (HOT and NEUTRAL) and distribute the 
controlled circuit (LOAD) to the fixture(s). The module 
connects to the terminal block and performs dimming 
control of four electronic low-voltage or incandescent 
loads. The maximum load is 10 amps for any controlled 
circuit, limited to 16 amps total per module. The unit 
requires 120VAC 60 Hz, 1 phase input voltage. An 
oversize heat sink dissipates heat efficiently. There are 
LEDs on the module to indicate communication to a 
Cresnet

 network, input power to the module, and output 

power to the load. 

NOTE:  

When connecting to an Arc Fault Breaker, 

the load should not exceed 1000 watts.  

Industry Compliance 

This product is Listed to applicable UL Standards and 
requirements by Underwriters Laboratories Inc. 

     

(E103692)

 

Installation 

The terminal block and module must be mounted into a 
Crestron Automation Enclosure by a licensed electrician, 
in accordance with all national and local codes.  

CAUTION:  

This equipment is for indoor use only 

and needs to be air-cooled. Mount in a well-
ventilated area. The ambient temperature must be 
32

°

F to 104

°

F (0

°

C to 40

°

C). The relative humidity 

must be 0% to 90% (non-condensing).  

Terminal blocks are installed along the left side of single-
wide enclosures and along the outside edges (left and 
right sides) of double-wide enclosures. Modules are 
installed along the right side of single-wide enclosures 
and side-by-side in the center of double-wide enclosures. 
When installing modules and terminal blocks in a double-
wide enclosure, be sure to invert units on the right side so 
that they can be properly wired. Refer to the illustrations 

shown in the next column when considering the location 
of terminal blocks and modules within an enclosure.  

NOTE:  

Modules and terminal blocks must be 

installed into the lowest available spaces and 
continue toward the top of the enclosure. 

Terminal Block & Module Locations (Single-wide Enclosure) 

CRESTRON

N OUT 4

N OUT 3

N OUT 2

N OUT 1

1 FEED

120VAC 60 Hz

16A MAX

9A MAX/CKT

CLX-1DELV4

GROUNDING

TERMINAL

BLOCK

DIM 4

DIM 3

DIM 1
DIM 2

4 DIM

LINE

TERMINAL

BLOCK

N IN

MODULE

 

Terminal Block & Module Locations (Double-wide Enclosure) 

Crestron Electronics, Inc.

 

Installation Guide – DOC. 5989A

 

15 Volvo Drive   Rockleigh, NJ 07647

 

(2002071)

 

Tel: 888.CRESTRON

 

08.05

 

Fax: 201.767.7576

  

Specifications subject to 

 

www.crestron.com

 

change without notice.

 

TERMINAL BLOCK

(RIGHT)

CRESTRON

N OUT 4

GROUNDING TERMINAL BLOCKS

TERMINAL BLOCK

(LEFT)

N OUT 3

N OUT 2

N IN

N OUT 1

DIM 4

DIM 3

DIM 1
DIM 2

LINE

1 FEED

120VAC 60 Hz

16A MAX

9A MAX/CKT

4 DIM

CLX-1DELV4

MODULE

N OUT 4
N OUT 3
N OUT 2
N OUT 1

N IN

DIM 4
DIM 3
DIM 2
DIM 1

LINE

CRESTRON

CLX-1DELV4

120VAC 60 Hz

16A MAX

9A MAX/CKT

1 FEED

4 DIM

 

Summary of Contents for CLT-1DELV4

Page 1: ...e air cooled Mount in a well ventilated area The ambient temperature must be 32 F to 104 F 0 C to 40 C The relative humidity must be 0 to 90 non condensing Terminal blocks are installed along the left side of single wide enclosures and along the outside edges left and right sides of double wide enclosures Modules are installed along the right side of single wide enclosures and side by side in the ...

Page 2: ...cuit has been tested for electrical faults and the module has been installed Refer to Module Installation on next page NOTE Use copper conductors only rated 75 C 2 With the circuit breaker turned off connect the circuit feed HOT and NEUTRAL and controlled circuit LOAD wires to the terminal block per the markings provided on the wiring label as shown in the diagrams on this page Terminal blocks acc...

Page 3: ... terminal to which it should be connected Wires are pre stripped to inch Tighten to 9 in lbs Do not over tighten 3 If the module is being installed above another module within the enclosure attach the supplied module interconnect cable between the two modules The illustration below depicts the area within a double wide enclosure where the corners of four modules meet NOTE One wire on the module in...

Page 4: ...ges following repair of items under warranty shall be paid by CRESTRON shipping by standard ground carrier In the event repairs are found to be non warranty return freight costs shall be paid by the purchaser CRESTRON Limited Warranty CRESTRON ELECTRONICS Inc warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three 3 years from...

Reviews: