background image

IF-57xx Time Recording
Terminal

00-57xx-04xx

Terminal

Summary of Contents for Interflex IF-57 Series

Page 1: ...IF 57xx Time Recording Terminal 00 57xx 04xx Terminal ...

Page 2: ...n 7 2 2 Encrypted data transfer 8 3 Mounting the terminal 9 3 1 Installation site 9 3 2 Fastening the back panel of the housing 9 3 3 Mounting and connecting the PoE connector 11 4 Initial operation 12 4 1 Connecting the controller to the network 12 4 2 Checking and setting network parameters 14 4 3 Configuring the interfaces and the booking memory 16 4 4 Listing the configuration data of terminal...

Page 3: ... 2022 Interflex Datensysteme GmbH IF 57xx Time Recording Terminal 07 22 3 7 1 UK Declaration of Conformity 22 7 2 EU Declaration of Conformity 22 ...

Page 4: ...ection Technical specifications 20 This document apply both to terminals connected to the IF 6040 system via WLAN and to terminals connected via Ethernet The two types are only distinguished if necessary 1 2 Scope of delivery n Terminal with ordered reading technology and options n PoE connector n 14 pin flat conductor cable with suppression cores n Metal back panel n Accessory bag with mortise lo...

Page 5: ...devices u Please observe the applicable safety regulations and take all precautionary measures to ensure safe installation NOTICE Property damage due to transient overvoltages Transient overvoltages surges bursts in the energy supply network can lead to malfunctions and failures u Use suitable mains filters that are professionally installed and operated NOTICE Damage due to electrostatic discharge...

Page 6: ...0 V AC power supply to power supply unit if not pre installed NYM 3 x 1 5 mm2 Network cable RJ45 patch cable preferably shield braiding 100 m From category 5 Control cable floating sensors 100 m J Y St Y 2 x 2 x 0 6 mm2 J Y St Y 2 x 2 x 0 8 mm2 RS 485 bus cable to end devices 1200 m J Y St Y 2 x 2 x 0 6 mm2 J Y St Y 2 x 2 x 0 8 mm2 Connecting cable between I O controller board and terminal 100 m J...

Page 7: ...hanged between the device and the parent host system e g the IF 6040 system The host system causes the status of the device to be cyclically queried The device acknowledges the query either by sending a sign of life or status messages or booking data from the terminals The IF 6040 host system evaluates the data received and reacts accordingly e g by sending back a positive or negative response to ...

Page 8: ... 2 2 Encrypted data transfer Transmission credential terminal Data transmission between a credential and a terminal are subject to constantly changing requirements Interflex always supports the current credential and reader technologies Transmission terminal controller The transmission of data between terminal and controller takes place using an RS 485 two wire line which is routed within the secu...

Page 9: ...nce of 10 cm between the connecting cables and the nearest power cable n Installation height 1200 mm Minimum distances between RFID and BLE devices If several RFID devices are mounted too close together mutual interference may occur Thus the following minimum distances must be maintained The minimum distance for back to back installation depends on the nature of the wall in between Please note tha...

Page 10: ... box Fastening the back panel of the housing directly to the wall Fasten the back panel of the housing only to an even surface If the cables are surface mounted a spacer 75 5735 00xx is required u Screw the back panel of the housing to the wall through the holes 2 using the three screws provided Fastening the back panel of the housing via an appliance case If you are using an appliance case you wi...

Page 11: ...both screws provided 2 Insert the network cable into the cutout of the metal back panel and plug the RJ45 plug 2 into the socket of the PoE connector 3 Connect the PoE connector to the terminal via the flat cable with interference suppression cores 4 as shown in the figure Power supply and functional grounding There are two ways to power the terminal n Via a network cable the RJ45 connector of whi...

Page 12: ... connection in housing IF 4070 controller 75 4070 0002 service cable 4xxx connection via RJ45 IF 5xxx terminal 75 99 0006 Service cable 5xxx 4 1 Connecting the controller to the network You can connect the controller to the network via a service cable and the serial service interface or via WLAN with the IF ServiceApp IF ServiceApp Prerequisites ü Controller is connected to the IF ServiceApp Detai...

Page 13: ... entering a password are the network services started and the network connection can be established u Establish network connection After the power supply has been switched on the component executes the following actions n Boot the operating system n Start applications n Connect the components The start up procedure takes up to 30 seconds When the RUN LED lights up an SSH connection can be establis...

Page 14: ...k and the minus sign n lists all possible command options n Press the Enter key to confirm command lines and data n To save new data you must confirm the Write to EEPROM y n prompt by entering y for yes n Modified data only becomes effective after a restart e g after a cold boot n SSH connections must be properly terminated after configuration Setting the network parameters Via the netpar x comman...

Page 15: ...nection 3 Current profile netpar IPv4 address netmask 172 18 12 65 16 IPv4 gateway 172 18 70 1 IPv4 address netmask active 172 18 12 65 16 IPv4 gateway active 172 18 70 1 Port 2001 Hostname IF xxx fieldservice IF xxx The subnet mask is appended to the IP address as CIDR notation e g 172 18 70 23 16 CIDR notation Subnet mask 4 240 0 0 0 8 255 0 0 0 12 255 240 0 0 16 255 255 0 0 24 255 255 255 0 30 ...

Page 16: ...te bus 1 3 bus 2 3 bus 3 3 Number of bookings 1000 50 Notice Baud rate terminal bus 2 9600 8 ep 3 19200 8 ep appropr terminals only Protocol terminalbus 0 erfProt 1 rsiProt 9600 8 noParity Your license allows 16 terminals as maximum Description base address Base address max 16 No of term bus n Number of terminals on bus n IF LT64 at bus 2 Number of IF LT64 components at bus 2 Protocol bus n 0 term...

Page 17: ...eric hardware address with which the time access program manages the terminals TNo Host management number The numbers are configured in the time recording access control program and are displayed after the data has been loaded type Component e g terminal IF xxx HWU Hardware status e g 2 04 for MPU hardware HCS12 SWU Software status e g version 6 b display Display type type line x columns keys Keyp...

Page 18: ...et button 1 2 3 Warm boot A warm boot performs the following actions n Close application n Restart application Associated console command oc s or factory reset application restart Reboot A reboot performs the following actions n Close application n Shut down operating system n Boot operating system n Restart application 1 Set switches 2 Shortly press the Reset button 3 Wait until the RUN LED light...

Page 19: ... 3 Wait until the RUN LED lights up again permanently procedure can take up to 45 seconds 4 Reset switch position Associated console command oc c oder factory reset application Reset network settings to factory default The network settings are reset 1 Set switches 2 Shortly press the Reset button The previous network settings are not saved temporarily unlike in earlier variants Factory reset All f...

Page 20: ...nly SimonsVoss Active Technology IF 5735 BLE Read range RFID 40 cm BLE optional Display Capacitive 4 3 inch color display resolution of 480 x 272 pixels Keypad IF 5735 PIN entry possible Signaling Audible Buzzer Visual Color LEDs Data interfaces Ethernet network connection with SSH TTL service interface Inputs IF 5735 Up to two I O controller boards with 2 floating sensors each optional Output rel...

Page 21: ...8 mm Color Black or white Installation type Surface mounted Cable feed Flush mounting surface mounting with spacer possible Weight 0 4 kg Housing material Thermally tempered white glass on a polycarbonate body 6 Disposal Once its service life comes to an end the device must be disposed of properly as electronic waste You can dispose of the device yourself or return it to the supplier ...

Page 22: ...cense information and the links to the OpenSource projects are available for download on the product in the directory home fieldservice app docs Source code and updates are provided in the directory Software Firmware Controller on the Interflex FTP server https ftpservice interflex de The information contained in this manual is to the best of our knowledge accurate and reliable However errors or m...

Reviews: