Rack 1:
RF Module (PM1, repeat for PM2 through PM4):
B+ Control Setpopint
Minimum Module DC Current
Minimum Module Low Voltage PS
B+ Limit Setpoint
Maximum Module DC Current
Maximum Module Low Voltage PS
B+ Sample
Average Module DC Current
Average Module Low Voltage PS
PDM Input
Minimum Module B+ Voltage
Minimum Module RF Drive(%)
SCR Contact (open/closed)
Maximum Module B+ Voltage
Maximum Module RF Drive (%)
AC Sample
Average Module B+ Voltage
Average Module RF Drive (%)
Highest Avg PM Temp
Minimum Module Modulation
Minimum Module Temperature
DC Current
Maximum Module Modulation
Maximum Module Temperature
Rectifier Temperature
Average Module Modulation
Average Module Temperature
+15 V
Minimum Module PA Voltage
Minimum Module Fan Speed
-15 V
Maximum Module PA Voltage
Maximum Module Fan Speed
+30 V
Average Module PA Voltage
Average Module Fan Speed
+48 V
DC Current
B+ Voltage
PDM Duty Cycle
PA Voltage
Low Voltage Supply
RF Drive Duty Cycle
Temperature
Fan 1 Speed
Fan 2 Speed