![Nautel NX5 AM Operation & Maintenance Manual Download Page 18](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218018.webp)
NX5 OPERATION & MAINTENANCE MANUAL
DESCRIPTION
PAGE 3.1.10
VERSION 0.1 2015-08-01
Shutback:
Shutbacks can be caused by the following alarms: SWR Shutback (exciter), Fast SWR Shutback
(controller), Over-Current Shutback (exciter), Over-Voltage Shutback (exciter) and Arc Shutback
(controller).
During a single shutback event (see
), the transmitter reduces the output
power to 0 W, and remains in that state for 100 ms. This allows time for an arc or transient
fault to clear. After 100 ms, the output power exponentially ramps up (to the power set point
or the power limit set by the exciter, whichever is lower).
After 30 s, the transmitter returns to full power under control of the normal ALC. When a
shutback occurs, the cutback accumulator is set to a normalized value of 1. This value decays
at a rate of 1/60 of a second (0.0167 s) so after 60 s, the accumulator value returns to 0 and
the shutback event is no longer in memory.
Figure 3.1.3: Shutback Event