![Nautel NX5 AM Operation & Maintenance Manual Download Page 60](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218060.webp)
NX5 OPERATION & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
PAGE 3.2.40
VERSION 0.1 2015-08-01
AM-AM and AM-PM Correction Screens
The exciter linearizes the transmitter’s magnitude (envelope) path and phase (RF drive) path by using
two correction parameters -
AM-AM Correction
(see
AM-PM Correction
(see
), which can be viewed as instrument panels.
Figure 3.2.28: AM-AM Correction
AM-AM Correction
This panel displays the amplitude correction being applied to the magnitude signal. The x-axis
represents the input signal amplitude and the y-axis represents the gain correction applied for a given
amplitude value.
Click on the panel to display a cursor in the approximate area on the trace. The cursor position (LUT
index and gain) is noted in the upper, right-hand corner of the panel. Click in other areas of the
instrument panel to provide a coarse adjustment of the cursor position.
Use the left and right buttons to make fine adjustments to the cursor position.
Use the up or down button to maximize (if it was minimized) or minimize (if it was maximized) the
panel size.