NX5 OPERATION & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
PAGE 3.2.4
VERSION 0.1 2015-08-01
User Interface Options
The user can interface with the NX5 using one of four methods:
Locally, using the the front panel push-buttons (RF On, RF Off and Local/Remote, see
) and the front panel UI and its navigational buttons (see
Remotely, via a LAN connection, using the advanced user interface (AUI) pages (see
Interface (AUI), on page 3.2.15
).
Remotely, via remote input/output (I/O) wiring connected to the control interface PWB (A4) (see
the NX5 Pre-installation Manual for I/O details).
SNMP, which is used to communicate transmitter control commands (e.g., RF on/off, main exciter,
active preset, power adjustments, etc.) as well as monitor data such as alarm states and meter
values. SNMP communication is configurable using the remote AUI (see
for more information).
See the complete menu hierarchy illustrated in
Figure 3.2.1
and
Figure 3.2.2
(for the local front panel
menu) and
Figure 3.2.3
(for the remote AUI menu). When a user interfacing function can be performed
from both the front panel display and the remote AUI, both are described in this section.