![Nautel NX5 AM Operation & Maintenance Manual Download Page 29](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218029.webp)
NX5 OPERATION & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.1 2015-08-01
PAGE 3.2.9
Front Panel Pushbuttons
The front panel contains three pushbutton switches that provide local control of the transmitter’s RF on/
off status and the local/remote operational control status (see
).
Figure 3.2.4: Front Panel Pushbutton Switches
RF
On
- Press the pushbutton switch to turn on the RF power stage and cooling fans. The
RF
On
LED will be on (amber) when the RF power stage is on and the external interlock circuit is
intact. The transmitter will operate at the level stored in the selected preset.
RF
Off
- Press the pushbutton switch to turn off the RF power stage. The
RF
Off
LED will
be on (amber) when the RF power stage is off.
NOTE
: The
RF
On
and
RF
Off
LEDs may blink if there are alarms occurring that prevent the
transmitter from enabling the RF power stage (e.g., interlock open, combiner matching, etc.)
Local/Remote
- Press the switch to toggle between “remote enabled” (
Remote
amber LED
on; local and remote control) and “remote disabled” (
Remote
LED off; local control only). The
transmitter’s local controls are always enabled so the
Local
LED is always on. In
Local
only
mode (
Remote
amber LED off), the front panel switches and UI control transmitter operation
and all of the remote controls (except the external interlock) are disabled. In
Remote
enabled
mode, control of transmitter functions is also provided to the remote (web-accessed) AUI or
remote input/output control on the control/interface PWB. The bottom of the remote AUI
home page will display the control status. When remote control is enabled, both the
Local
and
Remote
buttons are green. When remote control is disabled, only the
Local
button is green.
Front Panel UI
The front panel UI is 4 x 20 character graphic LCD display (see
). The UI can
be controlled by its adjacent keypad. The UI contains a menu-based series of pages that serve specific
functions. Similar interfacing, as well as more advanced functionality, is available on the remote AUI
(see
Front Panel UI Screens, on page 3.2.12
RF On
RF Off
Local
Remote
Status LEDs
Switches
Summary of Contents for NX5 AM
Page 2: ......
Page 4: ......
Page 8: ...NX5 OPERATION MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 1 2015 08 01 ...
Page 216: ...NX5 OPERATION MAINTENANCE MANUAL ROUTINE MAINTENANCE PAGE 3 3 12 VERSION 0 1 2015 08 01 ...
Page 219: ......