![Nautel NX5 AM Operation & Maintenance Manual Download Page 153](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218153.webp)
NX5 OPERATION & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.1 2015-08-01
PAGE 3.2.133
Power Thresholds
The
Power Thresholds
page (see
) allows you to set two distinct low forward power
thresholds the transmitter. These thresholds are for monitoring purposes only. The transmitter will not
shut back if these thresholds are crossed, but alarm notifications are generated for each of the two
thresholds (
Low Forward Power Threshold 1
and
Low Forward Power Threshold 2
) on the
Transmitter
Status
page.
Figure 3.2.114: System Settings - Power Thresholds
1.
Select
Power Thresholds
from the left side of the
System Settings
page to open a related
window on the right side of the page.
2.
Enter the desired low power threshold level for each of the two options, noting the level represents
the percentage of the normal operating setpoint. The default settings for
Low Forward Power
Threshold 1
and
2
are 50% and 25%, respectively.
3.
Click
Apply
to activate the change(s) or click
Cancel
to abort.