![Nautel NX5 AM Operation & Maintenance Manual Download Page 50](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218050.webp)
NX5 OPERATION & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
PAGE 3.2.30
VERSION 0.1 2015-08-01
Transmitter Alarms and Log - Using the Front Panel UI
When you select
View Status -> View Alarms
or
View Status -> View Log
from the front panel UI’s
Main Menu
(see
), you can view various active or logged events, respectively, of the NX5.
These parameters are likely displayed on multiple pages and require that you scroll to view all of them.
NOTE
: This screen is for viewing purposes only and does not offer the same level of analytical features
as the remote AUI’s Logs page (see
Figure 3.2.18: View Alarms and View Logs Screens
The
View Alarms
screen displays only the names of alarms that are currently active. The
View Logs
screen shows a chronological list of all alarms (up to 2000) that have occurred since the last time the
logs were cleared. Older events are discarded.
Use the up and down buttons to scroll through the list of alarms or logged events.
Refer to the NX5 Troubleshooting Manual to cross-reference the alarm name to possible causes and
troubleshooting tips.
When you select and activate
Clear Log
from the
View Status
menu, you can delete all logged events.
Use the
Reset Alarms
command in the front panel UI’s
Main Menu -> Reset Alarms
screen to
attempt to clear any latching alarms that are holding the transmitter in an “off-air” or reduced power
state. If the offending alarm has cleared, the transmitter should resume operation. See
Current entry
being viewed
Total # of
log entries
Date of event
yyyy/mm/dd
Time of event (24 hr)
hh:mm:ss
Event name
Event state