![Nautel NX5 AM Operation & Maintenance Manual Download Page 139](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218139.webp)
NX5 OPERATION & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.1 2015-08-01
PAGE 3.2.119
Envelope Equalization
The
Envelope Equalization
) allows you to load or capture a set of envelope
equalization curves. You can
Load
or
Delete
curves in the list; you can also capture a curve. When you
select
Capture
, the EQ Frequency Response window is displayed. Click
Done
to capture the curve, type
a name for the curve, then click
Save
(or
Cancel
).
Value changes are not typically required.
Envelope equalization curves correct for the frequency response of the magnitude path, dominated by
the response of the modulator filter. By applying a test signal and monitoring the output of the
transmitter, the exciter will use an LMS (Least Mean Squares) algorithm to generate a filter in an
attempt to find a complementary response to the frequency response of the magnitude path (out to
approximately 70 kHz). Applying the proper equalization curve will result in a flatter frequency
response, and improved spectral performance in digital modes of operation, where the frequency
content of the magnitude signal can be significant, as far out as 100 kHz.
Figure 3.2.103: Precorrection Envelope Equalization
CAUTION!
Selecting the Wide Band Noise training signal (see
)
applies full-scale white noise modulation. To avoid undesirable output or possible
antenna damage, it is highly recommended that you perform these calibrations
while operating the transmitter into a test load.
Wide Band Noise
Current Input