NX15/NX25 Operations and Maintenance Manual
Routine maintenance
Issue 6.0 2019-01-31
Page 3-7
Inspecting lightning protection systems
You should inspect the lightning protection systems that are connected to your NX15/NX25
transmitter, ac power, RF feedline, antenna and tower periodically to ensure that your site,
equipment and personnel are fully protected.
Interval
Every 6 months.
Parts and tools
Depends on your site, but may include a DVM, ladder, binoculars, and continuity tester.
Procedure
Perform the following steps to test the lightning protection systems:
1. Test the continuity between ground available at your lightning arrestor and ground
available on various pieces of equipment connected to the transmitter. Ensure that
there is no resistance (0 ohms).
2. Physically inspect the lightning arrestor to ensure that all connections are tight. Also
look for any sign of scoring or burning (indications of possible damage from earlier
lightning strikes).
3. Using binoculars, visually inspect the hardware on the tower. Look for charred,
broken or frayed connections and corrosion.