NX15/NX25 Operations and Maintenance Manual
Description
Issue 6.0 2019-01-31
Page 1-13
Average Reflected Power Foldback
If the average reflected power, calculated over a nominal 5 s period, exceeds a limit of 4% of
rated power, the output power is gradually reduced in order to maintain a reflected power that
is less than this limit. This gradual reduction in power into high VSWR allows the transmitter
to continue to operate into VSWR levels as high as 1.5:1 at full carrier power and even higher
VSWR levels when the carrier power is reduced. This VSWR protection is intended to protect
against short or open circuits when the transmitter is turned on, as well as non-transient faults
such as a poorly tuned antenna system.