NX15/NX25 Operations and Maintenance Manual
Operating the transmitter
Page 2-42
Issue 6.0 2019-01-31
Figure 2.27: Power Distribution Graph
Power distribution graph.
See
. The exciter measures the relative power levels of
the signal and determines the probability of exceeding a given power level, relative to the
average power. The data is plotted in the
Power Distribution Graph
as a CCDF
(complementary cumulative distribution function). The x-axis displays the relative power level
in dB, with the reference representing the average power. The y-axis displays the probability of
exceeding that power level. This graph can be used to assess the distribution of a given signal,
and provides an indication of the amount of peak power capability required.
Touch on the panel to display a cursor in the approximate area on the trace. The cursor
position (power gain and probability) is noted in the upper, right-hand corner of the panel.
Touch in other areas of the tool menu panel to provide a coarse adjustment of the cursor
position.
Use the left and right buttons to make fine adjustments.
Use the up or down button to maximize (if it was minimized) or minimize (if it was
maximized) the panel size.
Cursor
Left
Cursor
Right
Close
Minimize
(Maximize)
Summary of Contents for NX15
Page 2: ......
Page 4: ......
Page 8: ...NX15 NX25 Operations and Maintenance Manual Page viii Issue 6 0 2019 01 31...
Page 22: ...NX15 NX25 Operations and Maintenance Manual Description Page 1 14 Issue 6 0 2019 01 31...
Page 24: ...NX15 NX25 Operations and Maintenance Manual Page 1 12 Issue 6 0 2019 01 31 This page left bla...
Page 30: ......
Page 168: ...NX15 NX25 Operations and Maintenance Manual Routine maintenance Page 3 8 Issue 6 0 2019 01 31...
Page 177: ......