NX15/NX25 Operations and Maintenance Manual
Operating the transmitter
Page 2-102
Issue 6.0 2019-01-31
4. Press
Apply
to activate the change(s) or press
Cancel
to abort.
Power Thresholds
The
Power Thresholds
page (see
) allows you to set two distinct low forward
power thresholds the transmitter. These thresholds are for monitoring purposes only. The
transmitter will not shut back if these thresholds are crossed, but alarm notifications are
generated for each of the two thresholds (
Low Forward Power Threshold 1
and
Low Forward Power
Threshold 2
) on the
Transmitter Status
page.
Figure 2.74: System Settings - Power Thresholds
1. Select
Power Thresholds
from the left side of the
System Settings
page to open a
related window on the right side of the page.
2. Enter the desired low power threshold level for each of the two options, noting the
level represents the percentage of the normal operating setpoint. The default settings
for
Low Forward Power Threshold 1
and
2
are 50% and 25%, respectively.
3. Press
Apply
to activate the change(s) or press
Cancel
to abort.