NX15/NX25 Operations and Maintenance Manual
Operating the transmitter
Issue 6.0 2019-01-31
Page 2-101
Power Lockout
The
Power Lockout
page (see
) allows you to set a high power limit for the
transmitter. There is provision to set up to eight different limits (which can be used to
accommodate daytime/night-time patterns or different antennae), but only the selected limit is
active. You can also select a high power limit using a digital remote input (see
).
The transmitter power cannot increase beyond the active limit. For analog and hybrid modes
of operation the displayed power limits represent carrier power. For DRM mode, the
displayed power limits represent RMS power. If the active preset set point is greater than the
active lockout limit, a
High Power Lockout
alarm will appear on the
Transmitter Status
page.
For basic transmitter operation, you must configure and enable at least one of the eight high
power limits.
Max Power Lockout 1
is factory set for the transmitter’s maximum output power.
Set up a power lockout as follows:
Figure 2.73: System Settings - Power Lockout
1. Select
Power Lockout
from the left side of the
System Settings
page to open a related
window on the right side of the page.
2. Select the desired
Active Power Lockout
(
Max Power Lockout 1
through
8
) from the drop-
down menu
3. Enter the desired
Power Lockout
level for each of the eight lockout options, noting it
will represent the maximum allowable power level.
Summary of Contents for NX15
Page 2: ......
Page 4: ......
Page 8: ...NX15 NX25 Operations and Maintenance Manual Page viii Issue 6 0 2019 01 31...
Page 22: ...NX15 NX25 Operations and Maintenance Manual Description Page 1 14 Issue 6 0 2019 01 31...
Page 24: ...NX15 NX25 Operations and Maintenance Manual Page 1 12 Issue 6 0 2019 01 31 This page left bla...
Page 30: ......
Page 168: ...NX15 NX25 Operations and Maintenance Manual Routine maintenance Page 3 8 Issue 6 0 2019 01 31...
Page 177: ......