NX15/NX25 Operations and Maintenance Manual
Operating the transmitter
Page 2-112
Issue 6.0 2019-01-31
Changeover page - changing exciter transfer settings
The
Changeover
page (see
), accessed from the
Menu
page, allows control of exciter
auto-changeover.
Figure 2.83: Changeover Page
On this page, set the following exciter information:
•
Active Exciter
- indicates the exciter that is currently active.
•
Main Exciter
- indicates (in green) which exciter is considered to be the primary
exciter. Select
A
or
B
. The default exciter is
A
if the
Standby Exciter
is set to
No
.
NOTE:
Changing the setting may change the active exciter.
•
Auto Changeover
-
indicates (in green) if automatic exciter changeover is enabled.
Select
Yes
if automatic changeover is desired or
No
if user selected changeover is
desired.
NOTE:
you cannot change the setting if the
Standby Exciter
is set to
No.
•
Standby Exciter
- identifies whether or not a standby exciter is available. This is fac-
tory set and only requires adjustment if an exciter is removed or not functional.
Yes
indicates that a standby operation is available or desired.
No
indicates that a standby
operation is not available or desired.
Summary of Contents for NX15
Page 2: ......
Page 4: ......
Page 8: ...NX15 NX25 Operations and Maintenance Manual Page viii Issue 6 0 2019 01 31...
Page 22: ...NX15 NX25 Operations and Maintenance Manual Description Page 1 14 Issue 6 0 2019 01 31...
Page 24: ...NX15 NX25 Operations and Maintenance Manual Page 1 12 Issue 6 0 2019 01 31 This page left bla...
Page 30: ......
Page 168: ...NX15 NX25 Operations and Maintenance Manual Routine maintenance Page 3 8 Issue 6 0 2019 01 31...
Page 177: ......