Four Channels Click Meter Option
A-C-7
A-C.3.3 Click Mode
menu
The Click mode function has four commands:
•
Start
•
Clear: cancel and reset all data to start an idle test;
•
Chan #n selects the channel to be displayed;
•
Report
•
SETUP
Always use Esc button to return to the previous view/condition.
When CHAN #1 is selected the working receiver is the external PMM 9010,
when CHAN #2 is selected the L1 Led is green, the same for CHAN #3 and
L2, CHAN #4 and L3.
During a standard measurement the corresponding Led will be on for each of
the working channels.
Leds:
None = Chan #1 L1 = Chan #2 L2 = Chan #3 L3 = Chan #4
A-C.4 Self Calibration
Pressing the
Autocal
button PMM 9010 and 9010/Click4E start performing
their automatic self-calibration, using the internal precise tracking generator as
a reference.
The connection between the internal tracking generator and the input of the
receiver is done automatically inside the instrument.
The automatic Self Calibration, when the Four Channels Click meter Option is
operating, is performed in two successive steps. During the first step Chan #1
and #2 carry out their autocal, and automatically at the end of this the Chan #3
and #4 carry out their own autocal.
During the autocal each channel led blinks green.
To interrupt the self-calibration press the key
Abort
.
When the self-calibration is successfully finished a message is displayed:
In order to avoid any possible external influence, it is suggested to
disconnect all cables from the PMM 9010 and 9010/Click4E Option RF
ports during the self-calibration process.
Summary of Contents for PMM 9010 Series
Page 24: ...XXIV Safety considerations This page has been left blank intentionally ...
Page 42: ...2 10 Installation This page has been left blank intentionally ...
Page 66: ...6 6 Manual Mode Operating Instructions This page has been left blank intentionally ...
Page 72: ...7 6 Applications This page has been left blank intentionally ...
Page 92: ...9 14 General Information This page has been left blank intentionally ...
Page 112: ...10 20 Click Mode Operating Instructions This page has been left blank intentionally ...
Page 145: ...PMM 9030 9060 9180 Frequency Extension 11 33 Screwing the N N Adapter to BL 01 connector ...
Page 170: ...11 58 PMM 9030 9060 9180 Frequency Extension This page has been left blank intentionally ...
Page 178: ...12 8 PMM 9010 RMA Rack Mount Adapter This page has been left blank intentionally ...
Page 194: ...13 16 APD Mode Operating Instructions This page has been intentionally left blank ...
Page 230: ...14 36 Remote control This page has been intentionally left blank ...
Page 284: ...Suggerimenti Commenti Note Suggestions Comments Note ...