A-B-2
Additional RBW filters
It will be shown the following message; press
OK
to confirm.
The software will inform that the Dongle Code has been successfully stored;
Press
Ok
to close the program.
A-B.3 Analyzer Mode
To enter in the
ANALYZER
Mode
it’s enough to depress the Analyzer soft key
on the main screen.
In this mode the receiver works as a powerful Spectrum Analyzer and the
display shows the "spectrum analysis" in the frequency domain of a signal
tuned at a given frequency.
The analysis is done at the selected span frequency.
Using the marker facility the User can accomplish a very accurate
measurement of the signals either in frequency as well as in level.
A-B.3.1 RBW
Selection
The Spectrum mode function is divided into five sub windows:
•
Frequency
•
Resolution
Bandwidth
•
Level
•
Marker
•
Wide
Mode
The fifth button is used to change the spectrum view to
wide screen mode,
as shown in the picture 5-1, and with the
Esc
button the original view can be
restored.
Always use Esc button to return to the previous view/condition
.
A-B.3.2 MIL Filters
The
Resolution Bandwidth
command is used to select the bandwidth of the
measuring filter.
The three larger filters are selectable from the first RBW screen, and pressing
the
More RBW
button it is possible to select all the other filters.
These filters are mathematically modeled using FIR (Finite Impulse
Response) technique and they are exactly as required by the standards.
Four additional bandwidth filters are now available:
•
10 Hz MIL at -6dB
•
100 Hz MIL at -6dB
•
1 kHz MIL at -6dB
•
10 kHz MIL at -6dB
Summary of Contents for PMM 9010 Series
Page 24: ...XXIV Safety considerations This page has been left blank intentionally ...
Page 42: ...2 10 Installation This page has been left blank intentionally ...
Page 66: ...6 6 Manual Mode Operating Instructions This page has been left blank intentionally ...
Page 72: ...7 6 Applications This page has been left blank intentionally ...
Page 92: ...9 14 General Information This page has been left blank intentionally ...
Page 112: ...10 20 Click Mode Operating Instructions This page has been left blank intentionally ...
Page 145: ...PMM 9030 9060 9180 Frequency Extension 11 33 Screwing the N N Adapter to BL 01 connector ...
Page 170: ...11 58 PMM 9030 9060 9180 Frequency Extension This page has been left blank intentionally ...
Page 178: ...12 8 PMM 9010 RMA Rack Mount Adapter This page has been left blank intentionally ...
Page 194: ...13 16 APD Mode Operating Instructions This page has been intentionally left blank ...
Page 230: ...14 36 Remote control This page has been intentionally left blank ...
Page 284: ...Suggerimenti Commenti Note Suggestions Comments Note ...