Trouble with Initialization
When No Error is Displayed on the Printer's Liquid Crystal Display
1
• Ink cartridges are installed but not
recognized
1-1
1-2
• With the specified cartridge inserted securely, use the printer's self-diagnostic mode
"Sensor: No Ink" or "Sensor: No Cartridge" to check whether the presence of ink and car-
tridge are being detected normally.
→
Check using EXA1100 “[65YMCK] No Ink” procedure.
→
After adjustment or replacement, implement initial filling with the printer's self-diagnos-
tic "Adjust: Head Rank".
• With the specified cartridge inserted securely, use the printer's self-diagnostic mode
"Sensor: Cartridge" to check whether the status of the special cartridge is operating nor-
mally.
→
Check using EXA1080 "Insert special cartridge" procedure.
→
After adjustment or replacement, implement initial filling with the printer's self-diagnos-
tic "Adjust: Head Rank".