Mechanical System Faults
When Message is Displayed
1
2
3
4
• E065 Error X Motor
This message indicates that a fault
has occurred in the media feed motor
(X axis) while the printer was working.
This occurs when there is a large dif-
ference between the motor command
value and encoder feedback value.
• E069 Error X Encoder
This message indicates that a fault
has occurred in the amount of media
movement (X axis) while the printer
was working.
This occurs when there is no encoder
feedback.
• E071 Error X Timeout
This message indicates that a timeout
has occurred in the amount of media
movement (X axis) while the printer
was working.
This occurs when the pressure does
not reach its designated position.
• E073 Error X Overcurrent
This message indicates that a fault
has occurred due to an overload of
the media feed (X-axis) motor while
the printer was working.
1-1
1-2
1-3
1-4
1-5
1-6
• Use the self-diagnostic “Examination: History” to check the history of faults.
• Use the self-diagnostic “Aging: Media Feed Motor” with a setting of 50 times to check
whether the X Motor error occurs.
→
Check connectors J119 (X MOT) and J121 (X ENC) on the main board.
• Use the self-diagnostic “Examination: Encoder” to check Encoder X.
→
If it is no good, check the J121 (X ENC) cable connector.
• Check “Power Supply Voltage Check 24 DC”
• The X Motor assembly may be damaged.
→
Replace it.
• The main board assembly may be damaged.
→
Replace it.
No.
Symptom
Sequence
Items to be Confirmed
When Message is Displayed
Mechanical System Faults
1070
1140
1070
6020
1050
R E P
B A C
G O T O R e f . P a g e s
CAUTION:
If the Power supply board assembly and Main board assembly are
replaced without checking “24 V DC” on those, there is a risk that
the new boards may also be damaged.