Screw
Screws
R E P 1 2 7 0
Model Name: Rockhopper-46/62
R E P 1 2 7 0
Model Name: Rockhopper-46/62
How to replace the Maintenance Station Assembly
How to replace the Maintenance Station
Item
Replacement and Adjustment Procedure
1. Replacement
Procedure
Replace the Maintenance Station Assembly
1. Remove the Panel Cover.
2. Remove the Front Cover.
3. Remove the Y Rail Cover.
4. Remove the Panel Bottom Cover.
5. Remove the Panel Mounting Plate.
6.
Open the Control Box.
7.
Disconnect the pump motor connector J102.
8.
Undo the bundle of cables.
9.
Remove the waste liquid tube from the clamp.
10. Remove the Maintenance Station. (2 top screws/2 front
screws)
11. Assembling is the reverse of the removal procedure.
1. Carry out the Capping Position Adjustment.
2. Initialize the wiper count.
CAUTION: Be sure to clamp the waste liquid tube in the
proper position on the outside of the right
frame.
Otherwise the ink will spill and soil the floor
and clothing.
2. Adjustment
and
Examination