4.
Grip the Feed Roller tightly to pull it out from the slot.
5.
Install the new Feed Roller.
1
Insert the round end of the Roller in the mounting hole of the
slot that matches the roller number.
2
Angle the wheel end and push the wheel into the slot. Rotate
the handle up to lock it.
1
2
6.
close the feed path cover back into place, and then close the ADF
cover.
7.
click
i
(information) from the iDocScan touch panel, then click
Reset
next to the counter of Feed Roller 1 count and Feed Roller 2
count to set the counter back to 0.