5 Mounting
Maschinenfabrik Reinhausen GmbH 2020
165
5293079/01 EN
VACUTAP
®
VM-Ex
4. Swivel pressure ring segments back towards gear unit and tighten screws.
Ensure that the locking washer is between the screw head and pressure
ring segment and that the pressure ring segments are firmly in contact
with the gear unit housing.
Figure 195: Securing pressure ring segments
Fitting the horizontal drive shaft
To mount the horizontal drive shaft, proceed as follows:
1. Calculate dimension A between the shaft end of the upper gear unit and
the shaft end of the bevel gear and shorten the square tube to length A–
179 mm taking the insulator into account.
Figure 196: Shortening the square tube